AOC EN5200-ei Bedienungsanleitung Seite 29

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 42
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 28
EN5200-ei
Page 29 of 42
BAdjust C1(6500) color-temperature
1Switch the chroma-7120 to RGB-Mode (with press “MODE” button )
2Switch the MEM .channel to Channel 4( with up or down arrow on chroma 7120 )
3The LCD-indicator on chroma 7120 will show x = 313 ±10, y = 329 ±10,
Y = 180 ±10 cd/m
2
4Adjust the RED of color3 on factory window until chroma 7120 indicator reached
the value R=100
5Adjust the GREEN of color3 on factory, until chroma 7120 indicator reached G=100
6Adjust the BLUE of color3 on factory, until chroma 7120 indicator reached B=100
7Repeat above procedure ( item 5,6,7) until chroma 7120 RGB value meet the
tolerance =100±2
Press reset key
Turn the POWER-button off to on to quit from factory mode.
10. EDID CONTENT
x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
00 00 FF FF FF FF FF FF 00 16 09 63 E5 0B 60 01 00
16: 12 0D 01 03 68 1E 17 82 2A 71 F5 9F 55 4B 99 24
32: 1C 4F 54 BF EE 00 01 01 01 01 01 01 01 01 01 01
48: 01 01 01 01 01 01 64 19 00 40 41 00 26 30 18 88
64: 36 00 30 E4 10 00 00 18 00 00 00 FF 00 31 32 33
80: 34 35 36 37 38 39 30 31 32 33 00 00 00 FD 00 37
96: 4B 1E 3F 08 00 0A 20 20 20 20 20 20 00 00 00 FC
112 00 45 4E 2D 35 32 30 30 65 69 0A 20 20 20 00 78
Note: Byte 0C, 0D, 0E, 0F means Serial No. Byte 10, 11 mean Manufacture Time. Byte
7F means checksum